ACC DECODER
ACC Decoder - Controller

ACC Decoder Controller The two-wire decoder version of Hunter’s most powerful controller for command of large and sophisticated sites. The versatility of the ACC controller grows even more powerful with the addition of the all-new, two-wire decoder system from Hunter. ACC-99D uses two-wire decoders to control up to 99 stations without giving up the arsenal of features in the ACC! The powerful overlapping, stacking array of programs, along with ACC’s dual programmable pump/master valve outputs, real-time flow monitoring, and up to four programmable sensor inputs, take full advantage of this controller’s high capacity.

Decoder installations are the fastest growing technology in irrigation control. Why? Because it saves copper wire, simplifies troubleshooting, permits rapid addition of new stations, minimizes trenching, and now, permits remote sensor operation over the two-wire path. The ACC-99D, Hunter's most powerful controller teamed with the most versatile decoders in the industry…an unbeatable combination for large sites with changing needs.
 
ACC DECODER CONTROLLER MODELS

ACC-99D – 2-Wire Decoder Controller with 99 station capacity, wall mount metal cabinet
ACC-99DPP – 2-Wire Decoder Controller with 99 station capacity, plastic pedestal
ICD-100 – Single-station decoder with surge suppression and ground wire
ICD-200 – Two-station decoder with surge suppression and ground wire
ICD-400 – Four-station decoder with surge suppression and ground wire
ICD-600 – Six-station decoder with surge suppression and ground wire
ICD-SEN – Two input sensor decoder with surge suppression and ground wire
IDWIRE1 – 14 AWG/1.6 mm dia. decoder wire (up to 10,000 ft./3 km)
IDWIRE2 – 12 AWG/2mm dia. decoder wire (up to 15,000 ft./4.5 km)
HFS – Hunter flow sensor, requires the use of an FCT-xxx
ACC-PED – Metal Pedestal for use with ACC-99D


DIMENSIONS

ACC-99D Cabinet : 12 3⁄8" H x 15 1/2" W x 6 7/16" D
(31.4 cm H x 39.4 cm W x 16.4 cm D)
• ACC-99D Metal Pedestal: 36 1⁄8" H x 15 1/2" W x 5" D
(91.5 cm H x 39.4 cm W x 12.7 cm D)
• ACC-99D Plastic Pedestal: 38 3⁄8" H x 21 9⁄16" W x 15 7⁄8" D
(97.5 cm H x 54.6 cm W x 40.3 cm D)
• Decoders:
ICD-100, 200, ICD-SEN - 3 5⁄8" H* x 1 1/2" W x 1/2" D
(92 mm H* x 38 mm W x 12.7 mm D)
ICD-400, 600 - 3 5⁄8" H* x 1 3/4" W x 1 1/2" D
(92 mm H* x 46 mm W x 38 mm D)
• Wire leads (all) - 18" L, 18 AWG dia.
(46 cm L, 1 mm dia.)
*Not including wire leads.


SPECIFICATIONS & FEATURES

Transformer Input: 120/230VAC, 50/60 Hz, 2A max at 120V, 1A max at 230V.
• Transformer output: 24VAC, 4A, @ 120VAC
• Decoder Line (path) output: 34V peak-to-peak
• Decoder Power draw: 40 mA per active output
• Solenoid capacity: 2 standard 24 VAC Hunter solenoids per output within 100 ft./33 m runs, up to 14 solenoids max simultaneous (includes dual P/MV outputs)
• Wiring, Decoder to solenoid: standard pair 18 AWG/1 mm to 100 ft./33 m (twisted improves surge resistance)
• 6 two-wire output paths to field decoders
• Two-way confirmation of decoder activation
• Two-way monitoring of sensor connections (ICD-SEN)
• Diagnostic LEDs with line status, signal activity, decoder and status
• Programmable decoder station IDs (from controller panel)

ACC-99D Decoder Systems include all standard features of the ACC controller, including:

• 6 automatic programs, with 4 custom manual (auxiliary) programs
• Dual pump/master valve outputs programmable by station
• 1 flow meter (diagnostics to station level) and up to 4 sensor inputs (programmable to program level)
• Programmable overlap or SmartStack by program with simultaneous station groups.
• Seasonal adjust, 0 to 300% in 1% increments by program
• Flow learning mode by station with programmable alarm thresholds
• Station run times up to 6 hours with programmable delay between stations (up to 4 hours)
• Self-diagnostic circuit breaker skips shorted stations and continues watering
• SmartPort® equipped for wireless remote control
• Test program feature allows for quick system checks
• IMMS 2.0 central system compatible
• Upgrade to ET capability
• Real-time Flow Monitoring capability built in, with actual flow histories (in GPM or metric) available when connected to Hunter HFS or other compatible flow meters.
• Flow-learning mode by station, with station-level diagnostics and alarm shutdowns.
• Easy Retrieve™ backup feature can restore schedules, run times, names and other settings to a saved setup
 
SPECIFICATION GUIDE
EXAMPLE: ACC - 99D - PED
MODEL
ACC
FEATURES
99D = 2-Wire Decoder Controller with 99 Station Capacity, Metal Cabinet
99DPP = 2-Wire Decoder Controller with 99 Station Capacity, Plastic Pedestal
OPTIONS USER INSTALLED
PED = Optional Metal Pedestal
ICD




IDWIRE1
IDWIRE2
100 = Single-station Decoder with Surge Suppression and Ground Wire
200 = Two-station Decoder with Surge Suppression and Ground Wire
400 = Four-station Decoder with Surge Suppression and Ground Wire
600 = Six-station Decoder with Surge Suppression and Ground Wire
SEN = Two Input Sensor Decoder with Surge Suppression and Ground Wire
14 Awg Decoder Wire (Up to 10,000 Ft./3km)
12 Awg Decoder Wire (Up to 15,000 Ft./4.5km
ACC-COM HWR = Hardwire Connection Communication Module for “Satellite” Installations
POTS = Regular Dial-up Telephone (RJ-11) Connection Communication Module for “Satellite” Installations
GSM = Cellular Connection Communication Module for “Satellite” Installations
GSM-E = Cellular Connection Communication Module (Cell Phone & Antenna Included) for International “Satellite” Installations
ACC-HWIM
RAD3
Terminal for Hardwire Connections (In- and Outbound Wire)
UHF Radio Communications Module (Antenna not Included)
HFS Hunter Flow Sensor, requires the use of an FCT-xxx tee fitting
 
Copyright © 2009 Shira for Trade & Agencies website